Version=5

;postcuring:	pro3dure CD-2: 20 min
;		NK Optik otoflash G171: =< 2.5 mm: 2 x 2000 flashes; 2.5 to 3.5 mm: 2 x 3000 flashes (flip after first set of flashes)
;V2.2 - 2025-11-28 - EK

[General]
Name="printodent GR-19.1OA MSI"
Heater Temperature=	40	
Minimum Temperature=	30	
Heater Enable=		true
Manufacturer=		"pro3dure medical"
Color=			"#80d4ff"
Industry=		"Dental"

[:/Gen-2UV/General]
Printer Classes=["MAX UV385", "PRO 4K UV385", "Ultra", "Max 2"]

[:/Gen-2UV/Curing]
;Light Intensity=	12		
Support Exposure=	120

Z=[24.00, 0.06]
Z=[36.00, 0.11]
Z=[48.00, 0.16]
Z=[60.00, 0.19]
Z=[72.00, 0.22]
Z=[84.00, 0.24]

Offset=			0.05			
Z Compensation=		0.1
Burn-In Layers=		1		
Burn-In Exposure=	0.5		
XY Scale=		1.0042
XY Compensation=	-0.03

[Delays]
Burn-In Wait Time (After Exposure)=	2
Burn-In Wait Time (After Separation)=	5
Burn-In Wait Time (After Approach)=	0 
Normal Wait Time (After Exposure)=	0.3	 
Normal Wait Time (After Separation)=	0 
Normal Wait Time (After Approach)=	0

[:/Not-4K/General]
Printer Classes=["MAX UV385", "PRO 4K UV385", "Ultra", "Max 2"]
Slice Thickness Presets=	[0.05, 0.1]
Slice Thickness Preset=		0.05

[:/Not-4K/Mechanics]
Separation Distance=		8 	; mm
Separation Velocity=		4.3 	; mm/s 
Approach Velocity= 		4.3	; mm/s 
Separation Acceleration= 	5 	; mm/s^2
Approach Acceleration= 		50 	; mm/s^2
Separation Pressure Limit=	300
Viscosity Range= 		1.4173	

[Support]
Leveling=	true
Leveling Height=2.0
Tallest=	false
Tallest Height=	0.0
Slope=		35
Side Feature=	2.0
Spacing=	1.5
Strength=	40
Torsion=	0
Intersupport=	false
Contact=	0.8 
Island=		0.8
Overshoot=	0.6
MaximumWidth=	2.3
Side Faces=	8
AspectRatio=	3.0

[Cure]  
Temperature=		50 ; degree Celsius
Minimum Temperature=	47 ; degree Celsius
;Dose=			0
Time=			300 ; s
Power Level=		100
Vacuum=			true
Vacuum Target=		0.010 ; bar
Minimum Vacuum=		0.020 ; bar
Gas=			false ;
;Gas Cycles=		1